What is Wavefront Aberrometry?

Diagnosing the degree of vision impairment is a difficult task for even experienced optometrists, since it depends on the subjective response of the person tested. Normally, it is based on reading out or describing letters or shapes on an eye chart. In many cases the person may not actually be reading out the letter seen, but the letter thought to be seen.

A solution has been developed for this issue, which is known as wavefront aberrometry.

Image Credit: Emiliano Pane / Shutterstock
Image Credit: Emiliano Pane / Shutterstock

Light is thought of as being a traveling wave, with the shape of the wave reflecting the movement of individual light photons. As this passes through the normal eye, the front of the wave (‘wavefront’) presents a flat shape, while irregularities in the wavefront represent defects in vision.

The specific types and degrees of aberrations in the shape of the wavefront reflect the different kinds of problems present in the eye. Consequently, aberrometry represents a technique of measuring these changes or distortions in the path the light travels.

What are the advantages of wavefront aberrometry?

Wavefront aberrometry is an objective method of measuring refractive power, using a tool to measure the manner in which a light beam moves through the tested eye.

It offers detailed measurements of the movement of the light wavefront.

In this way it can be used in the diagnosis of both higher-order and lower-order refractive errors. Higher-order errors refer to conditions that include complex visual defects, unlike lower-order errors such as nearsightedness, farsightedness and astigmatism.

In addition, the technique is useful as a guide in making of spectacles and contact lenses to offer sharper and clearer vision.

Formerly, higher-order aberrations such as spherical aberration were ignored, both in surgical and lens correction. However, being able to detect and evaluate them has allowed better vision correction and even fewer post-surgical artefacts.

How is wavefront aberrometry performed?

Commonly, the person places the chin on a chin rest built into the aberrometer and looks into the instrument at a spot of light. The light passes through the pupil and is reflected back by the retina. The wavefront of the reflected beam is recorded and compared to that of the reference wavefront. All the points of variation are recorded and measured, creating in turn an optical fingerprint.

Wavefront Optimized LASIK Explained

The method used to identify vision errors is based on wavefront measurements, calculated using Zernike polynomials. This produces a topographic image of the distorted wavefront. This is used to design very accurate correction lenses or to guide refractive surgery. In fact, it is actually used intraoperatively to deliver maximum accuracy of lens correction following phakic surgery.

There are three different ways to analyze the aberrometry findings. These are outgoing wavefront aberrometers, ingoing retinal imaging aberrometers, and ingoing feedback aberrometers. The technique employed will change the speed at which results are available, the range of refractive error, as well as the potential to analyze and measure different aberrations.

Nevertheless, it is better to combine these methods with medical imaging or with topographic maps. With proper analysis, wavefront aberrometry enables the detection and treatment of conditions that impair vision at each stage of light passage through the eye. This includes all the stages from the tear film in front of the cornea to the retina itself. It also aids to understand how contact lenses actually affect the whole optic system of the eye.

Further Reading

Last Updated: Apr 3, 2019

Dr. Liji Thomas

Written by

Dr. Liji Thomas

Dr. Liji Thomas is an OB-GYN, who graduated from the Government Medical College, University of Calicut, Kerala, in 2001. Liji practiced as a full-time consultant in obstetrics/gynecology in a private hospital for a few years following her graduation. She has counseled hundreds of patients facing issues from pregnancy-related problems and infertility, and has been in charge of over 2,000 deliveries, striving always to achieve a normal delivery rather than operative.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Thomas, Liji. (2019, April 03). What is Wavefront Aberrometry?. News-Medical. Retrieved on January 02, 2024 from https://www.news-medical.net/health/What-is-Wavefront-Aberrometry.aspx.

  • MLA

    Thomas, Liji. "What is Wavefront Aberrometry?". News-Medical. 02 January 2024. <https://www.news-medical.net/health/What-is-Wavefront-Aberrometry.aspx>.

  • Chicago

    Thomas, Liji. "What is Wavefront Aberrometry?". News-Medical. https://www.news-medical.net/health/What-is-Wavefront-Aberrometry.aspx. (accessed January 02, 2024).

  • Harvard

    Thomas, Liji. 2019. What is Wavefront Aberrometry?. News-Medical, viewed 02 January 2024, https://www.news-medical.net/health/What-is-Wavefront-Aberrometry.aspx.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post
You might also like...
CU professor of ophthalmology receives grant to study Parkinson's disease biomarkers