ELISA, or Enzyme-Linked Immunosorbent Assay, is a tool used to detect and quantify substances, such as peptides, proteins, antibodies, and hormones. It involves the immobilization of an antigen or antibody onto a surface, followed by the addition of a sample to be analyzed. Detection is dependent on a specific antigen-antibody reaction.

ELISA plate with orange and yellow color change - picture taken by Jarun Ontakrai

Jarun Ontakrai | Shutterstock

What to do before running an ELISA

An ELISA test should always be performed in replicates (duplicates or triplicates) so as to achieve enough number of samples to calculate the standard deviation and coefficient of variation. The coefficient of error should be maintained less than 20%. If the calculated error is high, then errors arising due to pipetting, contamination of plates and reagents, evaporation, and/or temperature have to be evaluated.

Standard curve

A standard curve is used to measure the concentration of the sample. First, the absorbance values of standard concentrations (pg/ml) are plotted. A negative curve is also done which does not contain any standard sample data and is used to detect and measure background noise. For an accurate measurement, this background value must be subtracted from the standard curve.

The absorbance values of known concentration can be plotted as a positive control. The concentration of the target protein is derived by first calculating the mean absorbance and then using the standard curve to estimate the concentration.

Dilution factors should also be taken into account. For example, if the sample has been diluted fourfold, then the absorbance should be multiplied by four prior to using the standard curve to derive the concentration.

Coefficient of variation

The definition of coefficient of variation is the ratio of standard deviation and mean – i.e. standard deviation (σ)/mean (µ). Large values of coefficient of variation indicates inaccuracies due to pipetting or mixing of reagents between wells, bacterial or fungal contamination, drying out of wells, or temperature variations.

Spike recovery

The value obtained after running the ELISA test depends on how a targeted protein interacts with the antibodies, and this interaction is compared to a standard protein curve. Several factors - including buffer, matrix and heterophilic antibodies - can affect the binding of the sample, so this must be taken into account when determining the accuracy of an ELISA.

A spike assay can be performed to determine the accuracy of ELISA results. In this assay, a known amount of recombinant protein is added or spiked in to the sample. Then, using the standard curve the amount of material is measured. Large deviations in the measured values can indicate errors due to unknown elements in the assay.

Linearity assay

Linearity assay is also used to determine the accuracy of ELISA. In this case, the ‘spiked sample’ is serially diluted to 1:2, 1:4 and 1:8. If the concentration of the altered sample is detected, and if the results do not display a linear change in the measurements, it may indicate errors in the accuracy of ELISA.

In some cases, errors may be observed at certain concentrations and no longer observed at lower concentrations. In such instances, the sample may have to be diluted before the concentration measurements are performed.

Troubleshooting

Background noise can be caused by a number of factors, including:

  • Insufficient washing of the wells
  • Contaminated wash buffers
  • Too much detection reagent
  • Cross-reactivity of the antibody
  • Precipitation of the buffer and/or analyte

Sometimes, poor standard curve may be generated. This may be due to errors in standard solution, degradation of standard, standard is improperly reconstituted, or if the curve does not fit the scale. Considering the latter, plotting can be done using different scales, such as log-log or 5 parameter logistic curve.

Further Reading

Last Updated: Jan 2, 2019

Dr. Surat P

Written by

Dr. Surat P

Dr. Surat graduated with a Ph.D. in Cell Biology and Mechanobiology from the Tata Institute of Fundamental Research (Mumbai, India) in 2016. Prior to her Ph.D., Surat studied for a Bachelor of Science (B.Sc.) degree in Zoology, during which she was the recipient of an Indian Academy of Sciences Summer Fellowship to study the proteins involved in AIDs. She produces feature articles on a wide range of topics, such as medical ethics, data manipulation, pseudoscience and superstition, education, and human evolution. She is passionate about science communication and writes articles covering all areas of the life sciences.  

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    P, Surat. (2019, January 02). ELISA: How to Analyze Experimental Results. News-Medical. Retrieved on January 02, 2024 from https://www.news-medical.net/life-sciences/ELISA-How-to-Analyze-Experimental-Results.aspx.

  • MLA

    P, Surat. "ELISA: How to Analyze Experimental Results". News-Medical. 02 January 2024. <https://www.news-medical.net/life-sciences/ELISA-How-to-Analyze-Experimental-Results.aspx>.

  • Chicago

    P, Surat. "ELISA: How to Analyze Experimental Results". News-Medical. https://www.news-medical.net/life-sciences/ELISA-How-to-Analyze-Experimental-Results.aspx. (accessed January 02, 2024).

  • Harvard

    P, Surat. 2019. ELISA: How to Analyze Experimental Results. News-Medical, viewed 02 January 2024, https://www.news-medical.net/life-sciences/ELISA-How-to-Analyze-Experimental-Results.aspx.

Comments

The opinions expressed here are the views of the writer and do not necessarily reflect the views and opinions of News Medical.
Post a new comment
Post